Mechanical Products - 15 Amp Panel Mount Push to Reset Circuit Breaker CBM15 - Series 18
$25.99
SKU CBM15(01
This Listing is for One American Made 15 Amp Push to Reset Circuit Breaker - Panel Mount
Mechanical Products 1800-T0-1-2E-0150-02 . Packaged under MVP stock code CBM15
UL 1500 Ignition Protection
Compliances - MIL-STD-202, SAE J553, ABYC-E11, SAE J1428
Trip Free
Made in USA
Mounting: #10 Eyelet Holes
Terminals: #8-32 Screws
Replaces Klixon CDM-15
Robust design for Harsh Environments
The Series 18 was designed for the harshest of environments. The weatherproof and ignition proof characteristics are especially well suited to applications in the Marine, RV, Heavy Equipment, Trucks, Buses and Battery Chargers. All materials for the Series 18 were carefully chosen for resistance to UV and flammability. Equipment that must perform in the most demanding environmental conditions relies on the Series 18. The Series 18 uses a double-break design to achieve increased short-circuit interruption capability. The push-to-reset actuator is trip-free, ensuring the Series 18 cannot be forced to continuously maintain a closed circuit if an overload condition exists.
Maximum Voltage Ratings: 120VAC and 32VDC.
Ultimate Trip Minimum: ultimate trip of 100% of rated current at 25°C/77°F
Maximum ultimate trip of 135% of rated current at 25°C/77°F
Dielectric Strength 1,500VAC
Interrupt Capacity Style 0 & 1
Tested per UL 1077: 3000A (32VDC) SAE J553: COMPLIANT
Resettable Overload Capacity 10x rated value
Inrush Capacity 35X rated capacity for 1/2 cycle (0.008sec.)
Endurance 32VDC @ 100 cycles, 4X rating (Type III) 32VDC @ 100 cycles, 4X rating 1/2 hr (Type I)
Meets J553 requirements
Voltage Drop Max voltage drop 0.8V at rated current
Operating Temperature Range -54°C/-65°F to 60°C/140°F
Weight 1.375 oz. (39 gm.)
Ignition Protected Conforms to USCG Title 33, CFR, Section 183.410(a) per UL1500 testing
Ingress Protection Conforms to weatherproof requirements of SAE J1428
Corrosion Conforms to Mil-STD-202, Method 101, Test Condition A, for 96 hours under a 5% salt spray.
Humidity Conforms to Mil-STD-202, Method 106, for 240 hours at 95% RH.
Shock Rated to withstand 100g per Mil-STD-202, Method 213, Test Condition A. Vibration Rated to withstand 10g per Mil-STD-204, Test Condition A.
Regulatory Compliance Summary:
Interrupt Capacity: SAE J553, *UL1077
Ignition Protected: UL1500
Endurance: SAE J553
Dielectric Strength: *UL1077
Shock, Vibration, Corrosion, Humidity: Mil-STD-202 Weatherproof: SAE J1428 CE Marked (Tested per UL1077 methods)